Solar Inverter & Battery Sizing Calculator

Load-Shedding & Solar Sizer

Accurate continuous wattage, inductive startup surge & lithium battery capacity sizing

All Tools
Quick Presets:
4.5 hrs
1 hr 4.5 hrs (Standard) 12 hrs 24 hrs
85% DoD
Usable DoD Limit:
Auto (48V)

48V/51.2V is the industry standard for installations > 3kW to minimize heavy copper cable thickness and fire risk.

+25% Margin
Power Factor (PF):

🔌 Appliance Load Schedule 8 Active

Select devices you need running during power outages

•
Inductive Surge Multipliers applied automatically
⚡ Recommended System Sizing Standard 48V Hybrid
5.0 kW Inverter
+ 10.24 kWh Lithium LiFePO4 Storage

Provides comfortable backup for a 4.5h Stage 4 load-shedding slot with safety margin.

Inverter Load Utilization: 32% Loaded
Running: 440W Inverter Max: 5,000W

Electrical Specifications Breakdown Calculated in Real-Time

Continuous Load
440 Watts
0.44 kW
Peak Inductive Surge
980 Watts
2.2x of continuous
Min. Inverter Capacity
0.55 kW
0.65 kVA (@ 0.85 PF)
Energy Consumption
1.49 kWh
1,494 Wh per outage
Recommended Battery Bank: 1x 5.12 kWh Pack
Nominal Capacity 1.91 kWh
Capacity in Ah 37.3 Ah @ 51.2V
Usable Depth 85% DoD

Standard commercial LiFePO4 batteries are sold in 5.12 kWh (100Ah 51.2V) or 2.56 kWh (50Ah) modules. Over-sizing provides cycle longevity and emergency buffer.

Battery Autonomy Matrix (Hours of Run-Time) With 1x 5.12 kWh Pack

100% Load 9.9 hrs @ 440W
75% Load 13.2 hrs @ 330W
50% Load 19.8 hrs @ 220W
Eco (25%) 39.6 hrs @ 110W

Calculated using usable battery capacity factoring 92% inverter conversion efficiency and chosen DoD.

☀️ Solar PV Array Sizing (Optional Hybrid)

5.0 Peak Sun Hours
Required Solar Array 1.15 kWp Daily generation: ~4.5 kWh
550W Tier 1 Solar Panels 2 Panels 1.10 kWp Installed

Assumes average South African insolation of 5.0 Peak Sun Hours per day and 78% system performance ratio (wiring, inverter MPPT, temperature derating).

💰 Inverter vs Generator Running Cost

Massive Savings
Petrol Generator (4.5h) R214.65 ~1.8 L/hr @ R26.50/L
Battery Recharge (Grid) R6.04 1.62 kWh @ R3.65/kWh
Savings after 100 outages: R20,861 saved

⚡ Electrical DB Board Sub-Circuit Split Guide SANS 10142-1 Best Practice

Why splitting your distribution board into Essential and Non-Essential circuits saves R50,000+

✅ Essential Sub-Board (Inverter / Battery Backed) Always On

Connected to the Inverter UPS output. Runs seamlessly during load-shedding with <10ms automatic transfer time.

  • • All indoor & perimeter LED lighting circuits
  • • Wi-Fi router, fiber ONT, security alarm & CCTV cameras
  • • Primary kitchen refrigerator & chest freezer
  • • Home office workstation, laptops & TV plugs
  • • Gate motor & garage door opener
⛔ Non-Essential Grid Board (Eskom-Only / Solar Day) Switched Off during Outages

Directly connected to incoming municipal power or the inverter's AUX / Smart Load port. Never draws from battery at night.

  • • Electric geyser (3,000W element drains a 5kWh battery in 90 mins!)
  • • Electric stove, oven & induction hob
  • • Swimming pool pump (should run on solar daytime timer only)
  • • High-capacity air conditioning units (unless using solar daytime diversion)
  • • Electric tumble dryer & underfloor heating

📖 Solar & Inverter Engineering FAQ Guide

1. Why does inductive startup surge matter so much?

Appliances with electric motors and compressors (refrigerators, freezers, borehole pumps, air conditioners) require 3x to 6x their continuous operating power for 1-3 seconds to start spinning from a dead stop. If your inverter does not have enough surge capacity or headroom, it will trip with an overload error code (e.g. F08 or F51).

2. Why choose Lithium (LiFePO4) over Lead-Acid or Gel batteries?

Lead-acid and Gel batteries can only safely discharge to 50% Depth of Discharge (DoD) before damaging their plates, yielding only 300 to 500 cycles (dead in ~1 year under Stage 4 load shedding). Lithium Iron Phosphate (LiFePO4) batteries safely discharge to 85-90% DoD and offer 6,000+ cycles (10 to 15+ years of daily cycling), making them 4x cheaper over their lifetime.

3. When should I choose 12V, 24V or 48V DC systems?

Under Ohm's Law (Amps = Watts / Volts), running a 3,000W load at 12V requires 250 Amperes, demanding massive 70mm² copper cables and posing extreme fire risks. At 48V, that same 3,000W load requires only ~62.5 Amperes. Therefore, any system sizing at 3 kW or higher must be 48V/51.2V DC. 12V and 24V are strictly for portable trolleys and small apartments.

4. What is the difference between kVA and kW?

kW (Kilowatts) is real, working electrical power that does useful work. kVA (Kilovolt-Amperes) is apparent power (Voltage × Amperage). The relationship is governed by Power Factor: kW = kVA × PF. For modern pure sine wave residential solar inverters, the power factor is typically 0.85 to 1.0. A 5 kVA inverter with a 0.9 power factor produces 4.5 kW of continuous usable output.